12.
Creating a print queue manually on OpenUnix
10.

Changing the Default Values

You can change the default values of a print queue by the following procedure.
192
11.
If the above file exists, enter the following command.
/opt/toshiba/tap/bin/printconf_import \
–a <queue name> IP_ADDRESS \
rm /opt/toshiba/tap/bin/flag_<queue name>
Restart your lpd.
1.
Log on to the root account.
2.
Open your Linux/Unix editor.
3.
Create the following file.
/etc/lp/interfaces/<queue name>.conf
4.
Add a line as below in the <queue name>.conf.
dest=<IP address>
5.
Save the file.
6.
Enter the following command:
chmod +x <queue name>.conf
7.
Enter the following command:
chown lp:lp <queue name>.conf
8.
Enter the following command:
For e-STUDIO4511 Series
lpadmin -p <queue name> -v /dev/null -I any \
-i /usr/lib/lp/model/net_est4511
For e-STUDIO450 Series and e-STUDIO280 Series
lpadmin -p <queue name> -v /dev/null -I any \
-i /usr/lib/lp/model/net_estbw
9.
Enter the following command:
accept <queue name>
Enter the following command:
enable <queue name>