Connecting Ac Input Power; Ac Power Input Labeling - HP rp7440 Service Manual

User service guide, fourth edition - hp integrity rx7640 and hp 9000 rp7440 servers
Hide thumbs Also See for rp7440:
Table of Contents

Advertisement

7.
Route and connect the server power connector to the site power receptacle.
For locking type receptacles, line up the key on the plug with the groove in the receptacle.
Push the plug into the receptacle and rotate to lock the connector in place.
WARNING!
verifying that the cabinet has been wired into the site AC power supply correctly. Failure
to do so may result in injury to personnel or damage to equipment when AC power is applied
to the cabinet.
8.
Set the site power circuit breaker to ON.
9.
Set the server power to ON.
10. Check that the indicator light on each power supply is lit.

Connecting AC Input Power

The server can receive AC input power from two different AC power sources. If two separate
power sources are available, the server can be plugged into the separate power sources, increasing
system realibility if one power source fails. The main power source is defined to be A0 and B0.
The redundant power source is defined to be A1 and B1. See
label scheme.
NOTE:
When running the server with a single power source, either A0 and B0 or A1 and B1
should be used. All other combinations are not supported. Either combination requires two
power cords.
Figure 3-25 AC Power Input Labeling
The server has two power cord configurations:
All four line cords (preferred configuration)
Cords A0 and B0 only
A single-line-cord configuration is not allowed.
The power cord configuration is passed to the operating system using the pwrgrd (Power Grid)
command. Each of the five selections in the pwrgrd command matches one of the configurations.
The appropriate option should be selected for the actual line cord configuration. With the correct
configuration selected, the LEDs should be green. when the pwrgrd command is invoked, the
following menu is displayed.
MP:CM> pwrgrd
72
Installing the Server
Do not set site AC circuit breakers serving the processor cabinets to ON before
Figure 3-25
for the AC power input
MP/SCSI Core I/O card
Slot 0
MP/SCSI Core I/O card
Slot 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Integrity rx76409000 rp7440

Table of Contents