Epson S1C33210 Technical Manual page 443

Cmos 32-bit single chip microcomputer
Table of Contents

Advertisement

ADD9–ADD0: A/D converted data (D[1:0]) / A/D conversion result (high-order) register (0x40241)
Stores the results of A/D conversion.
The LSB is stored in ADD0, and the MSB is stored in ADD9. ADD0 and ADD1 are mapped to bits D0 and D1 at
the address 0x40241, but bits D2 through D7 are always 0 when read.
This is a read-only register, so writing to this register is ignored.
At initial reset, the data in this register is cleared to "0".
MS: A/D conversion mode selection (D5) / A/D trigger register (0x40242)
Selects an A/D conversion mode.
Write "1": Continuous mode
Write "0": Normal mode
Read: Valid
The A/D converter is set for the continuous mode by writing "1" to MS. In this mode, A/D conversions in the range
of the channels selected using CS and CE are executed continuously until stopped in the software.
When MS = "0", the A/D converter operates in the normal mode. In this mode, A/D conversion is completed after all
inputs in the range of the channels selected by CS and CE are converted in one operation.
At initial reset, MS is set to "0" (normal mode).
TS1–TS0: Trigger selection (D[4:3]) / A/D trigger register (0X40242)
Selects a trigger to start A/D conversion.
When an external trigger is used, use the CFK52 bit to set the K52 pin for #ADTRG.
When a programmable timer is used, since its underflow signal (8-bit timer) or comparison match B signal (16-bit
timer) serves as a trigger, set the cycle and other parameters for the programmable timer.
At initial reset, TS is set to "0" (software trigger).
CH2–CH0: Conversion channel status (D[2:0]) / A/D trigger register (0X40242)
Indicates the channel number (0 to 3) currently being A/D-converted.
When A/D conversion is performed in multiple channels, read this bit to identify the channel in which conversion is
underway.
At initial reset, CH is set to "0" (AD0).
CE2–CE0: Conversion end-channel setup (D[5:3]) / A/D channel register (0x40243)
Sets the conversion end channel by selecting a channel number from 0 to 3.
Analog inputs can be A/D-converted successively from the channel set using CS to the channel set using this bit in
one operation. If only one channel is to be A/D converted, set the same channel number in both the CS and CE bits.
At initial reset, CE is set to "0" (AD0).
CS2–CS0: Conversion start-channel setup (D[2:0]) / A/D channel register (0x40243)
Sets the conversion start channel by selecting a channel number from 0 to 3.
Analog inputs can be A/D-converted successively from the channel set using this bit to the channel set using CE in
one operation. If only one channel is to be A/D converted, set the same channel number in both the CS and CE bits.
At initial reset, CS is set to "0" (AD0).
S1C33210 FUNCTION PART
(D[7:0]) / A/D conversion result (low-order) register (0x40240)
Table 2.7 Trigger Selection
TS1
TS0
Trigger
1
1
External trigger (K52/#ADTRG)
1
0
8-bit programmable timer 0
0
1
16-bit programmable timer 0
0
0
Software
EPSON
IV ANALOG BLOCK: A/D CONVERTER
B-IV-2-11

Advertisement

Table of Contents
loading

Table of Contents