d) Use [+] or [-] to set the value for the frequency which is connected, and then press [!] or
["] to close the dialog box. (Available range: HIGH; 40 – 220 kHz, LOW; 25 – 220 kHz)
e) To operate the transducer in reduced power (for example, when vessel is in dry dock),
press ["] to select PWR REDUCTION, and then press [+] or [-] to open the dialog box.
f) Press [+] or [-] to turn the power reduction ON, and then press [!] or ["] to close the
dialog box.
6. Confirm settings and turn off the power.
3.3

Water Temperature Sensor Setting

If a water temperature sensor is connected, set up as follows:
1. Turn on the power and turn the [FUNCTION] switch to the MENU position.
2. Press [!] and [+] to select SYSTEM at the top of the screen.
3. Press ["] to select TEMP SETTING, and then press [+] to open that menu.
4. The cursor is selecting TEMP UNIT; press [+] or [-] to open the dialog box.
5. Press [+] or [-] to select the temperature unit, and then press [!] or ["] to close the
dialog box.
OFF
ON
DISP
ALM
TX/RX
TEMP SETTING
TEMP UNIT
:
˚F
TEMP INPUT
: SENSOR
TEMP ADJUST
:
+0.00˚F (-20 +20)
TEMP OUTPUT
: OFF
TEMP READOUT : OFF
TEMP GRAPH
: OFF
TEMP COLOR
: STD
Select temperature unit.
[-/+]: Change set, [EXIT]: Exit
TEMP SETTING menu
C
E/S
SYSTEM
F
3. INITIAL SETTINGS
3-7