1. MOUNTING
1.4
Optional Water Temperature Sensor ST-02MSB,
ST-02PSB
Select a suitable mounting location considering the following points:
• Select a mid-boat flat position. The sensor does not have to be installed perfectly perpendicular.
The sensor must not be damaged in dry-docking operation.
• Select a place apart from equipment generating heat.
• Select a place in the forward direction viewing from the drain hole, to allow for circulation of cool-
ing water.
• Select a place free from vibration.
Procedure
1. Dry-dock the boat.
2. Make a hole of approx. 51 mm (2.0") in diameter in the mounting location.
3. Unfasten locknut and remove the sensor section.
4. Apply high-grade silicone sealant to the flange of the sensor.
5. Pass the sensor casing through the hole.
6. Face the notch on the sensor casing and tighten the locknut.
7. Set the sensor section to the sensor casing and tighten the locknut.
8. Launch the boat and check for water leakage around the sensor.
Face "notch"
toward bow.
Flange nut
51
(2.0")
Coat with
Brim
silicone
ø77
(3.0")
sealant.
7
Locknut
123mm (4.8")