Optional Water Temperature Sensor St-02Msb, St-02Psb - Furuno DFF1 Operator's Manual

Network sounder
Hide thumbs Also See for DFF1:
Table of Contents

Advertisement

1.6
Optional Water Temperature Sensor ST-02MSB,
ST-02PSB
Select a suitable mounting location considering the following points:
• Select a mid-boat flat position. The sensor does not have to be installed perfectly
perpendicular. The sensor must not be damaged in dry-docking operation.
• Select a place apart from equipment generating heat.
• Select a place in the forward direction viewing from the drain hole, to allow for circu-
lation of cooling water.
• Select a place free from vibration.
Procedure
1. Dry-dock the boat.
2. Make a hole of approx. 51 mm in diameter in the mounting location.
3. Unfasten locknut and remove the sensor section.
4. Apply high-grade sealant to the flange of the sensor.
5. Pass the sensor casing through the hole.
6. Face the notch on the sensor toward boat's bow and tighten the flange.
7. Set the sensor section to the sensor casing and tighten the locknut.
8. Launch the boat and check for water leakage around the sensor.
Face "notch"
toward bow.
Flange nut
Coat with
silicone sealant.
Speed/Temperature sensor ST-02MSB, ST-02PSB
Locknut
51
123
Brim
φ77
10