Speed/Water Temperature Sensor Calibration - Furuno FCV-295 Installation Manual

Color lcd sounder
Hide thumbs Also See for FCV-295:
Table of Contents

Advertisement

Entering transducer data by transducer specifications
To connect the transducers which are not programmed, do as follows:
Note: The transducers of 53 - 65 kHz, 111 to 139 kHz and 171 - 183 kHz cannot be connected to
the FCV-295 because of noise.
1. At the XDCR Setting dialog box, select "XDCR Select" and press the ENTER key.
The following screen appears.
2. Press
to select "Manual", and then press the ENTER key.
3. If a high frequency transducer is fitted, press
ENTER key.
4. Press
to select "Connected" and then press the ENTER key.
5. Press
to select "Freq" and then press the ENTER key.
6. Press
or
to set the frequency of the transducer which is connected and then press the
ENTER key.
7. Press
to select "Band width" and then press the ENTER key.
8. Press
or
to set the value for the bandwidth and then press the ENTER key. If the band-
width is not entered manually, it is automatically set to 1/10 of the transducer frequency.
9. If a low frequency transducer is fitted, repeat steps 3 to 8.
Note: Leave the "Tx Power" at "Auto".
10.Press and hold down the [
3.3

Speed/Water Temperature Sensor Calibration

If the optional speed and/or water temperature sensor is connected, set it up as follows:
1. Turn on the power and press the MENU key.
The main menu and sub-menu appear.
2. Press
to select "System" and "Calib" and then press the ENTER key.
XDCR Type
Manual
to select "HF Connection" and then press the
Connected
Not connected
--- kHz
/BRILL] key to turn off the power.
13