Furuno FCV-1100L Installation Manual page 22

Color lcd sounder
Hide thumbs Also See for FCV-1100L:
Table of Contents

Advertisement

1. MOUNTING
Through-hull mount water temperature/speed sensor
ST-02MSB, ST02-PSB
Select a suitable mounting location considering the following:
Select a mid-boat flat position. The sensor does not have to be installed perfectly
perpendicular. The sensor must not be damaged in dry-docking operation.
Select a place apart from equipment generating heat.
Select a place in the forward direction viewing from the drain hole, to allow for circulation of
cooling water.
Select a place free from vibration.
1. Dry-dock the boat.
2. Make a hole of approx. 51 mm diameter.
3. Unfasten locknut and remove the sensor section.
4. Apply high-grade sealant to the flange of the sensor.
5. Pass the sensor casing through the hole.
6. Face the notch on the sensor toward boat's bow and tighten the flange.
7. Set the sensor section to the sensor casing and tighten the locknut.
8. Launch the boat and check for water leakage around the sensor.
Water temperature/speed sensor ST-02MSB, ST-02PSB
1-6
Face "notch"
toward bow.
Flange nut
Coat with
silicone sealant.
Locknut
51
123
Brim
77

Hide quick links: