Craftsman 919.152361 Owner's Manual page 10

120v inflator

Advertisement

Available languages

Available languages

Risk of Electrical
Shock, IMPROPER
GROUNDING
CAN RESULT IN
ELECTRICAL
SHOCK,
Do not modify the plug provided,
If
it does not fit the avaiBable outlet,
a correct
outlet
should
be installed
by a qualified
electrician,
Repairs to the cord set or plug
MUST be made by a qualified
emectrician,
Extension
Cords
If an extension cord must be used, be
sure it is:
a 3-wire extension cord that has
a 3-blade grounding ptug, and a
3-slot receptacle that will accept
the ptug on the product
in good condition
no longer than 50 feet
16 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases.
14, 12, 10, and 8
AWG may also be used.
Voltage
and Circuit
Protection
Refer to the specification
chart for the
voltage and minimum branch circuit
requirements.
Certain inflators can be operated
on a 15 amp circuit if the following
conditions
are met.
1.
Voitage supply through branch
circuit is 15 amps.
2.
Circuit is not used to supply any
other electrical needs (lights,
appliances,
etc.).
3.
Extension cords comply with
specifications.
4.
Circuit is equipped with a
15 amp circuit breaker or 15
amp time detay fuse. NOTE: If
compressor
is connected to a
circuit protected by fuses, use
only time delay fuses. Time delay
fuses should be marked "D" in
Canada and "T" in the US.
If any of the above conditions
cannot be met, or if operation of
the compressor repeatedly causes
interruption
of the power, it may be
necessary to operate it from a 20
amp circuit. It is not necessary to
change the cord set.
A10087
10-ENG