Risk of Unsafe Operation.
Vomtage sources,
moving parts,
or compressed
air sources
are exposed
when repairing
the compressor.
Personam injury can occur. Unpmug the compressor
before
attempting
any repairs.
PROBLEM
Motor will not
run.
CAUSE
Fuse blown, circuit breaker
tripped.
Extension cord is wrong
length or gauge.
Faulty motor.
CORRECTION
1. Check fuse box for blown
fuse and replace as
necessary.
Reset circuit
breaker. Do not use a
fuse or circuit breaker with
higher rating than that
specified for your particular
branch circuit.
2. Check for proper fuse.
You should be using a
"Time Delay" fuse.
3. Check for low voltage
problem.
4. Check the extension cord.
5. Disconnect the other
electrical appliances from
circuit or operate the
compressor
on its own
branch circuit.
Check the extension cord.
Contact a Trained Service
Technician.