Device Configuration Commands
7.4.7.2 Configuration Commands
7.4.7.2.1 port-backup
This command is used to enable or disable port backup for a uplink set
Syntax
port-backup <uplinkSetName>
no port-backup <uplinkSetName>
<uplinkSetName> - A string associated with uplink set as a convenience. It should be an
existing uplink set.
no - This command disable port backup for an existing port group.
Default Setting
None
Command Mode
Global Config
This command is used to set the failback time of port backup for a uplink set.
Syntax
port-backup <uplinkSetName> failback-time <value>
no port-backup <uplinkSetName> failback-time
<uplinkSetName> - A string associated with uplink set a convenience. It should be an
existing uplink set.
<value> - Time value is range from 1 to 60 seconds. Default value is 60 seconds.
no - This command set the failback time to default value for the specific uplink set.
Default Setting
60
Command Mode
Global Config
This command is used to move a port from active-port list to backup-port list.
Syntax
port-backup
no port-backup
163
Command Reference