Figure 2-1
1 C2RPS-CHAS2 chassis
2 C2RPS-PSM power supply module
Replacing an Installed C2RPS-PSM
To replace a PSM installed in an operating system, proceed as follows:
Caution: Observe all Electrostatic Discharge (ESD) precautions when handling sensitive
electronic equipment.
Precaución: Al trabajar con equipos electrónicos sensibles, tome todas las precauciones
de seguridad para evitar descargas de electricidad estática.
1.
Unplug the AC power cord of the PSM from the AC power source first, then from the
rear of the PSM.
2.
Loosen the captive screws securing the PSM until it is released from the chassis front
panel.
3.
Pull the PSM out and remove it from the chassis.
4.
Repeat steps 1 through 3 for each additional PSM you plan to remove.
C2RPS-PSM Installation
À
Â
Ã
3 Chassis power supply slot
4 Captive screws (2)
SecureStack C2 Installation Guide 2-3
Installing C2RPS-PSMs
Ã
Á