PLC-WM5500/WM5500L Expand Serial Command Functional Specifications

8.10.35 CF_KEYDIS Command

Command
"CF_KEYDIS_%1" [CR]
"NONE" ----------------------- RC and KEY are both enabled.
%1
"RC" ---------------------------- RC is disabled.
"KEY" -------------------------- KEY is disabled.
Disable RC and/or KEY functions
Details
(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable

8.10.36 CF_PJPINCODE Command

Command
"CF_PJPINCODE_%1" [CR]
%1
"0000 – 9999" ------------- Directly specify PJ PIN code
Enter PIN code to cancel PIN code lock (Available only in the normal Power ON
status)
PIN code can not be changed. (Only PIN code lock is canceled.)
*When PIN code Lock is enabled:
PIN code is matched ------------------------- Command is valid (Acceptable)
PIN code is mismatched -------------------- Command is invalid (Error code "102")
PIN code is beyond %1 available range ---- Command is invalid (Error code "?")
Details
*When PIN code lock is canceled:
PIN code is within %1 range ----------- Command is valid (Acceptable)
PIN code is out of %1 range ----------- Command is invalid (Error code is 102)
This command is only valid when "PJ PIN code" dialog is displayed to enter PIN
code after Power is ON and Countdown is completed.
When PIN code lock is set to "On1", it needs to send this command every time
the projector is turned on.
Acceptable
Response
Unacceptable

8.10.37 CF_SHUTRCPROT Command

Command
"CF_SHUTRCPROT_%1" [CR]
"ON" ------------------ Disable RC key from controlling Shutter (Protection On)
%1
"OFF" ----------------- Enable RC key to control Shutter (Protection Off)
Set valid / invalid of RC use on Shutter control function
Details
(Valid only when in the normal Power ON status)
Acceptable
Response
Unacceptable

8.10.38 CF_SHUTKEYPROT Command

Command
"CF_SHUTKEYPROT_%1" [CR]
"ON" --------- Disable key on the top panel from controlling Shutter (Protection On)
%1
"OFF" -------- Enable key on the top panel to control Shutter (Protection Off)
Set valid / invalid use of key on the top panel on Shutter control function.
Details
(Valid only when in the normal Power ON status)
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
50/88