Cf_Setpcadj Command; Cf_Orgmode Command - Sanyo PLC-WTC500AL - 5000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WTC500AL - 5000 Lumens:
Table of Contents

Advertisement

PLC-WTC500L Expand Serial Command Functional Specifications

8.5.8 CF_SETPCADJ Command

Command
"CF_SETPCADJ_%1" [CR]
None
%1
"EXT11-60"
1. Apply value set in PC Adjust Menu to projected image.
Specifying setting value directly in the following PC Adjust related commands
immediately reflects them on projected image, while issuing this command after
these commands also triggers the reflection. (Available only in the normal Power
ON status)
0û CF_FSYNC
0û CF_TDOTS
Details
0û CF_CLAMPPAHSE
0û CF_Hÿ POS
0û CF_Vÿ POS
0û CF_DDOTS
0û CF_DLINE
2. When "EXT11"~"EXT60" is specified in %1, "Ex Mode" (not like XGA1) is
displayed in "SYSTEM" menu.
Acceptable
Response
Unacceptable

8.5.9 CF_ORGMODE Command

Command
"CF_ORGMODE_%1" [CR]
When input signal is PC Analog;
"VGA1" ------------------------ Specify VGA1
"VGA2" ------------------------ Specify VGA2
:
:
"XGA1" ------------------------ Specify XGA1
:
:
"WXGA3" --------------------- Specify WXGA3
"1080I60" --------------------- Specify 1080i60
%1
"1080I50" --------------------- Specify 1080i50
"1035I" ------------------------ Specify 10350i
"720p60" --------------------- Specify 720p60
"720p50" --------------------- Specify 720p50
"575p" ------------------------- Specify 575p
"480p" ------------------------- Specify 480p
"575I" -------------------------- Specify 575i
"480I" -------------------------- Specify 480i
* When input signal is not PC Analog, error code "101" is returned.
After "EXT n" is set by PC control command such as CF_FSYNC/CF_TDOTS
and CF_SETPCADJ command, specify the signal originated with by issuing
this command.
Details
This command is used to specify projector internal settings such as whether or
not to get PC signal through IP (Available only in the normal Power ON status)
Note; To differentiate between 60Hz and 50Hz in 1080i and 720p, "60" or "50"
is necessary to add to the parameter in this command.
Acceptable
Response
Unacceptable
"000" [CR]
"101" [CR] --- When input is Video signal / No signal
"000" [CR]
"101" [CR] --- When Input is other than PC Analog
23/75