PLC-WL2500A / WL2501A/ WL2503A Expand Serial Command Functional Specifications
9.7.6
CR_SRCINP4 Command
Command
"CR_SRCINP4" [CR]
Details
Get selected source of Input 4_Video
Acceptable
Response
Request data
Unacceptable
9.7.7
CR_SRCINP5 Command
Command
"CR_SRCINP5" [CR]
Details
Get selected source of Input 5_S-video
Acceptable
Response
Request data
Unacceptable
"000_%1"[CR]
"VIDEO" ------------- Composite Video Input is selected
"Error code"[CR]
"000_%1"[CR]
"Sÿ VIDEO" -------- S-Video Input is selected
"Error code"[CR]
54/72