PLC-WL2500A / WL2501A/ WL2503A Expand Serial Command Functional Specifications
8.5.4
CF_H – POS Command
Command
"CF_H-POS_%1"[CR]
"0000~nnnn" --- Directly select Horizontal Position setting value
%1
"UP" -------------- Current Horizontal Position setting value + 1
"DN" -------------- Current Horizontal Position setting value - 1
Set Horizontal Position value of PC signal.
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Standby status or ALL is OFF, the value returns to original setting.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.5.5
CF_V – POS Command
Command
"CF_V-POS_%1"[CR]
"0000~nnnn" --- Directly select Vertical Position setting value
%1
"UP" -------------- Current Vertical Position setting value + 1
"DN" -------------- Current Vertical Position setting value – 1
Set Vertical Position value of PC signal
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Standby status or ALL is OFF, the value returns to original setting.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.5.6

CF_DDOTS Command

Command
"CF_DDOTS_%1"[CR]
"0256"~"nnnn" --- Directly select Display Dots setting value
%1
"UP" -------------- Current Display Dots setting value + 2
"DN" -------------- Current Display Dots setting value – 2
Set Display Dots value of PC signal
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Standby status or ALL is OFF, the value returns to original setting.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"nnnn" shows maximum value, it is current Total Dots value - Display Dots value
"000"[CR]
"Error Code"[CR]
"nnnn" shows maximum value, it is current Total Line value - Display Line value
"000"[CR]
"101"[CR] ---- When Input source is Video system
"nnnn" shows maximum value, it is current Total Dots value - Horizontal
Position value
Even number is available and when odd number is set, it is rounded out.
"000"[CR]
"Error Code"[CR]
22/72