Cf_Ptime Command; Cf_Ccaptiondisp Command; Cf_Ccaptioncolor Command - Sanyo PLC-WL2500A Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WL2500A:
Table of Contents

Advertisement

PLC-WL2500A / WL2501A/ WL2503A Expand Serial Command Functional Specifications

8.10.21 CF_PTIME Command

Command
"CF_PTIME_%1"[CR]
%1
"001" ~ "180" -----------Directly specify the time by minutes.
Set Countdown timer for P-timer function.
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.22 CF_CCAPTIONDISP Command

Command
"CF_CCAPTIONDISP_%1"[CR]
"OFF" ------------- Select Off
"CC1" ------------- Select CC1
%1
"CC2" ------------- Select CC2
"CC3" ------------- Select CC3
"CC4" ------------- Select CC4
Select channel of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Details
Note)Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video) and System is fixed
to NTSC.
Acceptable
Response
Unacceptable

8.10.23 CF_CCAPTIONCOLOR Command

Command
"CF_CCAPTIONCOLOR_%1"[CR]
"COLOR" ------- Select Color
%1
"WHITE" -------- Select White
Select color of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Details
Note)Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video) and System is fixed
to NTSC.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
40/72