(Warning) Indicator - Epson EMP-52 User Manual

Hide thumbs Also See for EMP-52:
Table of Contents

Advertisement

When Having Some Trouble

(Warning) Indicator

Status
High internal
Red
temperature
(overheating)
Problem with
Red
lamp
(0.5-
second
intervals)
Cause
The lamp will turn off automatically and
projection will stop. Wait for about 5 minutes
without operating the projector. After about 5
minutes have elapsed, unplug the power cable
and then check the following two points.
• Check that the air inlet and air outlet are
clear, and that the projector is not positioned
against a wall.
• If the air filter is dirty, it should be cleaned.
When the power cable is plugged back in, the
projector will return to its previous state, so
press the [Power] button on either the
projector's control panel or the remote control
to turn it back on. If the projector continues to
overheat even after the above points have been
checked, or if the indicators show a problem
when the power is turned back on, stop using
the projector, disconnect the power cable from
the electrical outlet, and contact your dealer or
the nearest address provided at "International
Warranty Conditions" in Safety Instructions/
World-Wide Warranty Terms.
Disconnect the power cable from the electrical
outlet and then remove the lamp and check if it
is broken. If the lamp is not broken, reinstall it.
Then reconnect the power cable and press the
[Power] button on either the projector's control
panel or the remote control to turn the power
back on.
If the indicators still show a problem, stop
using the projector, disconnect the power cable
from the electrical outlet, and contact your
dealer or the nearest address provided at
"International Warranty Conditions" in Safety
Instructions/World-Wide Warranty Terms.
Remedy or Status
62
: lit
: flashing
See
Page
p.16
p.73
p.76

Hide quick links: