Four-Pin Optional Sensor Harness; Red Wire; Black Wire; Blue, Green Wires - Directed Electronics AM1 Installation Manual

Hide thumbs Also See for AM1:
Table of Contents

Advertisement

four-pin optional sensor harness

RED wire

The red wire supplies constant power to the optional sensor.

BLACK wire

The black wire supplies ground to the optional sensor.

BLUE, GREEN wires

The blue and green wires are multiplex inputs. They are both tied to the same zone.
If an input of less than 0.8 seconds is supplied to either wire the Warn-Away
response will occur. An input longer than 0.8 seconds to either wire will initiate the
triggered sequence and report zone 4. This port can be used for optional sensors such
as: the 506T—glass breakage sensor, or the 504D—field disturbance sensor.

dealer master control loop

This 2-pin black connector when removed in disarmed state from the control module will
reset the system back to allow the full set of customer settings and remove the dealer remote
from memory.

door lock learn routine

Before the unit will respond to the factory remote keyless system, it must learn the
polarity of the door lock wires. To learn the lock polarity:
N N O O T T E E : : It is important that all the INPUT signals to the control module are in the rest sta-
tus state (no activity) before entering the learn routine. Wait at least 15-seconds after the
ignition is turned OFF to begin this rountine, or the unit will be placed in Valet
22
®
®
mode.