Chapter 3 Creating and Editing Screens
Property Description of Character Entry Elements
If YES is selected, the screen will show as the following figure when
inputting the setting value.
Display Asterisk
(*)
If this option is selected, the element can be displayed immediately
when switching the screen. Please note that this function is
designed to provide fast value refresh speed for the element which
performs communication frequently. Therefore, only 4 elements
(including display element and input element) can be fast refreshed
Fast Refresh
on one screen. If the user uses this function on too many elements,
it may affect the normal speed of HMI operation. So, we recommend
the user not to activate this function if not necessary. The user can
set the Fast Refresh Rate by clicking Screen > Screen Properties
command. There are three levels of the Fast Refresh Rate and they
are High, Medium and Low.
Use this option to force the current priority to be the lowest after the
Set Low Security
button is pressed. This can prevent the misoperation made by the
user (operator).
InterLock
When InterLock Address is set to be ON or OFF (this is determined
Address
by the property of "InterLock Level"), this button can be enabled.
InterLock Level
If this option is set, when the user presses the button, the system
will execute the command of this macro first and then perform the
Before Execute
operation of this button. But, if the state of the button is not
Macro
triggered by pressing the button (via macro or external signal), the
command of this macro will not be executed.