Delta Electronics DUP-B Series User Manual page 172

Human machine interface
Table of Contents

Advertisement

Read Address
Blink
Foreground Color
Line Size
Data Format
Revision May, 2010
Property Description of Dynamic Rectangle Element
Read Address +2
Read Address +3
Read Address +4
Read Address +5
Please note that when Variable Position option is set to No, the
internal memory address of Variable Size option will increase one
(one increment) automatically. (Read Address will represent the
right-bottom horizontal position (Right) of the element. Read
Address+1 will represent the right-bottom vertical position
(Bottom) of the element. Read Address+2 will represent the
foreground color of the element.)
The element can blink to remind the user. (Please refer to Table
3-8-2 Property Description of General Buttons.)
Used to set the foreground color of the dynamic rectangle
element.
The unit is Pixel and the range is within 1 ~ 8.
It provides BCD, Signed Decimal, Unsigned Decimal and Hex four
kinds of data format to define the read memory content.
Chapter 3 Creating and Editing Screens
The value of the Read Address+2 can be used
only when Variable Size option is set to Yes. It
is used to represent the right-bottom
horizontal position (Right) of the element, i.e.
the width.
The value of the Read Address+3 can be used
only when Variable Size option is set to Yes. It
is used to represent the right-bottom vertical
position (Bottom) of the element, i.e. the
height.
The value of the Read Address+4 can be used
only when Variable Color option is set to Yes.
It is used to represent the line color. The
range is different depending on selected HMI.
The range for 16 shades of gray model is
within 0 ~ 15, the range for 256 colors model
is within 0 ~ 255 and the range for 65536
colors is within 0 ~ 65535.
The value of the Read Address+5 can be used
only when Blink option is set to Yes. When the
value is higher than 1, the dynamic line
element will blink. If the value is 0, it will not
blink.