Chapter 3 Creating and Editing Screens
3.8.4

Bar Elements

3.8.4.1 Normal

HMI reads the value of the corresponding PLC specific address (register) and converts
the value to normal bar element and then displays it on the screen.
Read Address
Text
Text Size
Font
Text Color
Border Color
Foreground Color
Background Color
Style
Display Format
3-120
Fig. 3-8-21 Bar Elements
Property Description of Normal Bar Elements
The address can be internal memory or the controller address.
(Please refer to Table 3-8-2 Property Description of General
Buttons.)
The user can set the text, text size, font and text color provided by
Windows® to determine the text display on the element (Please
refer to Table 3-8-2 Property Description of General Buttons.)
Set the border color of the element
It is used to set the foreground and background color of the normal
bar element. For example, the foreground color of the following
example bar element is green and its background color is yellow.
Standard
The display progressing direction is from right to the
Left
left.
The display progressing direction is from left to the
Right
right.
The display progressing direction is from bottom to
Top
the top.
The display progressing direction is from top to the
Bottom
bottom.
Raised
Sunken