WARNING
!
Do not connect any neutral (white)
wire to this control. Incorrect wiring
will damage this control.
4. Connect one black wire of wall control
to the "hot" wire. Securely connect
wires with wire connectors supplied
(Figure 20).
5. Connect one black wire of wall switch
to the "load" (black) wire in wall box.
Securely connect wires with wire
connector supplied.
6. Screw wall control into wall box and
install
decorator
(included). Leave wall control in "OFF"
mode until fan installation is completed.
7. Refer to page 5 and complete the
ceiling fan installation.
HI
LIGHT
MED
LOW
FAN OFF
EMERSON
®
OFF
ON
FAN/LIGHT
WALL
CONTROL
Figure 20
3-WAY INSTALLATION
(On fan controlled by two different wall
controls) (See Figures 21 and 22.)
1. Disconnect power at circuit breaker or
remove fuse.
2. At all wall box locations remove
faceplates and screws from existing
controls. Pull controls out from wall
boxes and determine which wall box
contains the "hot" lead and which wall
box contains the "load" wire. Also,
identify traveler wires which are
common
to
both
Disconnect wires from existing controls
only. Do not attempt to disconnect any
wires not already connected to existing
controls.
2/15/06
3:21 PM
Page 14
3. Before installing wall control, place wall
control in "OFF" mode by pushing
"ON/OFF" switch to the "OFF" position.
Do not connect any neutral (white)
wire to this control. Incorrect wiring
will damage this control.
4. Install a wall control in the wall box
containing the "hot" wire first. Connect
the black wire of the wall control to the
"hot" wire. Securely connect wires with
wire connectors supplied.
5. Connect one black wire of the wall
style
faceplate
control to both remaining traveler wires
in the wall box and secure with wire
connector supplied.
NOTE: Retrofit 3-way installations are
likely to include two traveler wires
between the two wall boxes. In new
construction, only one traveler wire Is
required.
U
3-WAY WIRlNG DIAGRAM:
NEW CONSTRUCTION
HOT
WALL
BOX
BLACK
NEUTRAL
REMOTE CONTROL
RECEIVER LOCATED
WITHIN THE CEILING
COVER
Figure 21
6. Place wall control into wall box. Screw
in place and install decorator style
faceplate (included).
7. Next, install the other wall control into
the wall box containing the load wire.
Connect the black wire of the wall
control to the traveler wire(s) already
wall
boxes.
connected to the black wire (in the
other wall box). Secure with wire
connectors supplied.
8. Connect one black wire of the wall
control to the "load" (black) wire and
secure with wire connector supplied.
14
WARNING
!
FAN/LIGHT
HI
WALL
HI
LIGHT
LIGHT
MED
MED
LOW
LOW
CONTROL
FAN OFF
FAN OFF
EMERSON
®
EMERSON
®
OFF
ON
OFF
ON
LOAD
TRAVELER
BLACK
WIRE
GROUND

Advertisement