Separated Combustion Blower Unit Heaters - Modine Manufacturing PSH Installation And Service Manual

Separated combustion high efficiency gas-fired unit heaters
Table of Contents

Advertisement

SEPARATED COMBUSTION BLOWER UNIT HEATERS

A
H
GAS SUPPLY
CONNECTION
D (OPENING)
2
7 /
"
8
Dimensions (in inches) — BSH
Dimension
A
B
C
D
E
F
G
H
AA
BB
CC
DD
EE
FF
J (Round)
K
Natural Gas Connections
W
X
M
N
O
P
Blower
Q (Height)
Enclosure
Inlet Duct/R (Height)
(Accessory)
Filter Rack Width T
Width V
S (Ctr. to Ctr. of Blower Mtg. Holes
Motor Pulley Diameter
Standard Blower Pulley Diameter
Approx. Shipping Weight
On blower units L = C + P is distance from front of unit to back of blower enclosure and minimum of distance to wall.
Dimension from rear of unit burner box to center line of gas pipe connection is 6-23/32" for BSH 130 and 6-1/2" for all other models.
BSH 130 through BSH 225 – 4 holes. BSH 280 and BSH 340 – 6 holes.
Distance between mounting hole in unit casing and mounting hole on blower, except on 280 and 340, then distance from rear mounting hole in casing.
Motor pulley is adjustable.
Performance — BSH
Btu/Hr
Input
Btu/Hr
Model
Output
BSH 130
130,000
106,600
BSH 150
150,000
123,000
BSH 170
170,000
139,400
BSH 225
225,000
182,250
BSH 280
280,000
229,600
BSH 340
340,000
275,400
At 65°F ambient and unit fired at full rated input. Max mounting height as measured from bottom of unit, and without deflector hoods.
Note: Ratings shown are for elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea
level. (In Canada see Rating Plate.) Reduction of ratings requires use of high altitude kit.
Data listed is for standard 115-volt, 60-Hertz, single-phase motors. All single phase motors are totally enclosed and thermal overload protected.
L = C + P (APPROX.)
C
DD
F
N
X
CC
W
K
AA
G
K
E
B
S
COMBUSTION AIR
INLET COLLAR
(SIZES 130-225)
BB
FF
4
1
/
"
2
M
OVAL COLLAR FITS
6" ROUND PIPE FOR
MODELS BSH 280 & 340 ONLY
BSH 130
BSH 150
23-1/2
25-5/8
35-1/2
40-1/2
22
25
21-1/16
23-3/16
20
24
12-1/2
14-1/2
1
2
19-7/8
22
8
9
7-1/2
7-1/2
1
1/8
3-1/4
3-1/4
32-9/16
36
6-1/2
6-1/2
4
4
3/8-16
3/8-16
1/2
1/2
47-3/4
52-3/8
21
24-1/2
7-1/4
8-1/2
30
34
21-3/8
25
20
23-3/4
27-1/2
32-3/4
29
34
17-3/8
20-3/8
3
3
13
13
240
322
Note: Mounting heights and throws for BSH models, without ductwork or nozzles, and at a cfm yielding a 55°F
temperature rise are the same as those listed for equivalent size PSH units.
Outlet
CFM
Velocity
@ 55°F
@55°F
Temp.
Temp.
CFM
Rise
Rise
Range
1795
682
1161-1795
2071
596
1340-2071
2347
675
1519-2347
3068
781
1985-3068
3865
852
2501-3865
4636
869
3000-4636
5
9
/
"
16
P
J
3
/
"
4
O
Q x V
R x T
3
1
/
"
4
7
/
"
8
8
FILTER RACK
(OPTIONAL)
BLOWER
ENCLOSURE
(OPTIONAL)
BSH 170
BSH 225
25-5/8
25-5/8
40-1/2
40-1/2
25
23-3/16
26-3/16
24
14-1/2
14-1/2
2
22
9
7-1/2
7-1/2
1/8
3-1/4
3-1/4
36
6-1/2
6-1/2
4
3/8-16
3/8-16
1/2
52-3/8
52-3/8
24-1/2
24-1/2
8-1/2
8-1/2
34
25
23-5/8
23-5/8
32-3/4
32-3/4
34
20-3/8
20-3/8
3
13
322
Max. Mtg.
Heat
Air
Height (Ft.)
Throw (Ft.)
Temp.
@ 55°F
@ 55°F
Rise
Temp. Rise Temp. Rise
Range
55-85
11
55-85
10
55085
11
55-85
13
55-85
14
55-85
15
Heater Parts from ACF Greenhouses
The minimum recommended
installation clearance from top and
rear of unit (motor) is six inches.
Clearance to sides is eighteen
inches, and clearance at bottom
should equal "C" dimension shown
5
9
/
"
16
in table for each model.
4" ROUND FOR
BSH 130 thru 225
MODELS ONLY
COMBUSTION AIR
INLET COLLAR
(SIZES 130 - 225)
3
3 /
"
8
3
1 /
"
8
EE
BSH 280
33-5/8
40-1/2
25
25
31-3/16
24
24
2
1-5/8
25
30
9
9
7-1/2
1/8
1 3/8
3-5/8
36
36-1/16
5-7/8
4
6
3/8-16
1/2
3/4
5
16
52-3/8
17-15/16
8-1/2
34
36
25
25
23-5/8
42-7/8
34
44-1/4
20-3/8
3
3
13
9
344
436
Standard Motor Data
HP
Amps
RPM
30
1/4
5.4
1725
25
1/2
7.8
1725
30
1/2
7.8
1725
35
3/4
10.2
1725
40
1
13.2
1725
40
1
13.2
1725
BSH 340
40
40-1/2
25
37-1/2
24
1-5/8
36-3/8
9
7-1/2
1 3/8
3-5/8
36-1/16
5-7/8
6
3/8-16
3/4
5
16
58-1/2
22-1/16
8-1/2
36
25
23-5/8
42-7/8
44-1/4
20-3/8
3
9
510
Type
SP
SP
SP
SP
CP
CP
15

Advertisement

Table of Contents
loading

Table of Contents