Heater Lamp Removal; Power Supply Unit (Pwb-E) Removal - Epson ActionLaser 1300 EPL-3000 Service Manual

Table of Contents

Advertisement

Disassembly and Assembly

3.2.3.3 Heater Lamp Removal

Do not touch the glass swface of the lamp with your bare hands.
side set to the support plate side.
1.
Remove the fusing unit. (Refer to Section 3.23.2.)
2. Remove the CC screw (M3 x 8) for the heater lamp support plate, and remove it.
3. Remove the heater lamp.

3.2.3.4 Power Supply Unit (PWB-E) Removal

1. Remove the housing. (Refer to Section 3.2.l.l.)
2. Remove the rear frame. (Refer to Section 3.2.l.2.)
3. Disconnect connectors cN2, CN3, and CN40nthe power supplybcwd (PWB-E).
4. Remove 2 CC screws (M3 x 6) and 3 CP(0) screws (X43 x 6),
Figure 3-8. Removing the Power Supply Unit
Figure 3-7. Removing the Heater Lamp
and remove the power supply
..-'
Rev. A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Epl-3000Actionlaser 1300

Table of Contents