1.3.2 Optional Interface C82305*/C82306* (EPL-3000 only)

Type:
RS-232C or current loop
Asynchronous start-stop system
Synchronization:
X-ON/X-OFF (cannot be combined with
Protocol:
Transfer
300,600,1200,1800,2400, 4800,9600, or 19200 bps
speed:
Error handling:
Overrun error:
Parity error:
Framing error:
Breaking character: Ignored
Handshaking
When the vacant area for data in the input buffer drops to 256 bytes, the printer outputs an X~FF
code or sets the DTR signal level to LOW, indicating that the printer cannot receive more data.
Once the vacant area for data in the buffer recovers to 512 bytes, the printer outputs an X-ON code
or sets the DTR signal level to HIGH, indicating that the printer is again ready to receive data.
Rev. A
bit
Start bit:
1
Stop bit:
1 bit
Data length:
7 or 8 bits
Parity:
Odd,
Processed as missing data and replaced by "*"
Replaced by """
Replaced by "*"
even, or
none
with X~N/X-OFF)