DURKOPP ADLER 768 Setting Instructions Manual page 24

Table of Contents

Advertisement

6.10.2.3 Setting Positions with the V820 Control Panel
Entry of the code number for the technician level
Turn the main switch off.
All plugs on the controls of the sewing drive must be plugged in.
Press the "P" key and hold pressed.
Turn the main switch on. The display shows "C-0000"
Release the "P" key
Enter code no. 1907 with the numeric keys 0 to 9.
Press the "E" key. The first parameter, F-100, at the technician level is shown and the first
number blinks.
Setting the reference position
After entry of the code number press the "E" key.
The first parameter, F-100, at the technician level is shown.
Set the parameter F-170 with the keys 0 to 9.
Press the "E" key. Shown in the display = "F-170 Sr1"
Press the "B" key. Shown in the display = "F-170 PoS 0 ( )"
Turn the handwheel in the normal direction of turn until the character "( )" disappears from
the display, then turn farther until the reference position (needle point, with lowered needle,
at the level of the top of the needle plate) is reached.
Press the "E" key. The reference position is saved. Shown in the display "F- 171"
If the reference position was not saved, an error message appears in the display = "inF
E3". Turn the handwheel repeatedly until the desired reference position is reached.
Setting positions 1 and 2
The reference position is set. (see above)
Enter parameter "F-171".
Press the "E" key. Shown in the display = "Sr2"
Press the "B" key. Shown in the display = "F 171 1 xxx" = parameter value of pos. 1
If necessary, correct parameter value *. Either with the "+" and "-" keys or by turning the
handwheel.
Press the "E" key. Shown in the display = "F 171 2 xxx" = parameter value of pos. 2
If necessary, correct parameter value *. Either with the "+" and "-" keys or by turning the
handwheel.
Press the "E" key. Shown in the display = "F 171 1A xxx" = parameter value of pos. 1A
If necessary, correct parameter value *. Either with the "+" and "-" keys or by turning the
handwheel.
Press the "E" key. Shown in the display = "F 171 2A xxx" = parameter value of pos. 2A
If necessary, correct parameter value *. Either with the "+" and "-" keys or by turning the
handwheel.
Press the "P" key twice. The settings are completed, the programming level is exited
Check the positions. See Chapter 6.10.2.4
* Attention! The parameter values for the positions 1, 2, 1A and 2A are to be found on
the parameter sheet (accessories pack).
24

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents