6.11.5
Setting Parameter Values with the V820 Control Panel
Changing parameter values at the "Technician Level"
Entry of the code number for the technician level
–
Turn the main switch off.
–
All plugs on the controls of the sewing drive must be plugged in.
–
Press the "P" key and hold pressed.
–
Turn the main switch on. The display shows "C-0000"
–
Release the "P" key
–
Enter code no. 1907 with the numeric keys 0 to 9.
–
Press the "E" key. The first parameter, F-100, at the technician level is shown and the first
number blinks.
Selecting the parameters and changing the values
–
After entry of the code number the first parameter, F-100, is shown.
The first number of the parameter number blinks.
–
Enter the desired parameter number with the numeric keys 0 to 9.
–
Press the "E" key. The value of the selected parameter is shown.
–
The parameter value can be changed with the "+" and "-" keys.
–
Press the "E" key. The next parameter is shown
or press the "P" key - the same parameter is shown.
Saving changed parameter values
–
Press the "P" key, programming is ended.
–
Sew a complete seam, that is, step the pedal forward and then completely back.
The change is saved.
–
If no seam is sewn the change is lost.
–
Through renewed pressing of the "P" key one returns to the programming level.
Changing parameter values at the "Supplier Level"
Entry of the code number for the supplier level
–
Turn the main switch off.
–
All plugs on the controls of the sewing drive must be plugged in.
–
Press the "P" key and hold pressed.
–
Turn the main switch on. The display shows "C-0000"
–
Release the "P" key
–
Enter code no. 3112 with the numeric keys 0 to 9.
–
Press the "E" key. The first parameter, F-200, at the supplier level is shown.
–
Proceed as in "Selecting the Parameters and Changing the Values"
28
NOTE !
The altered parameter values are only then saved, when,
after exiting the programming level, a complete seam is
sewn, that is, step the pedal forward and then completely
back. If, after exiting the programming level, the drive is
immediately turned off the changes are lost.