10.

Ancillary equipment

10.1

Sewing lamp

Fitting the sewing lamp
Two sewing lamps are available as ancillary equipment for the class 768.
Fitting the halogen sewing lamp
A special fitment (order no. 0907 487519) is required for the halogen sewing lamp 1.
Unscrew arm cover 6.
Attach holder 5 with serrated lock washer 7 and screw 8 to the arm cover 6.
There is a tapped hole in the arm cover for this purpose.
Replace the arm cover 6.
Place the halogen sewing lamp 1 on the holder 5 and align.
Tighten locking screws 2 and 3.
Stick the cable-holder 4 to the rear of the sewing-machine arm.
Fitting the light-guide sewing lamp
A special fitment (order no. 9880 767001) is required for the light-guide sewing lamp 9.
Screw the light-guide sewing lamp 9 onto mounting plate 10 with countersunk
screws.
Attach the mounting plate 10 with countersunk screws to the rear of the
sewing-machine arm. There are tapped holes in the sewing-machine arm for this
purpose.
Screw the holder 11 for the light-guide 13 onto the head cover 12.
Screw the light-guide 13 with clamp 14 to the sewing-machine head.