Power Consumption Of The Vitroceramic Hob; Power Consumption Of The Volcanic Rock Grill - Caple GR1201 Gastron Instruction Manual

Cooking hobs/cookers
Table of Contents

Advertisement

3.4.3 Replacing the electric cable
To replace the electric cable, it is necessary to access the terminal board. It is located on the back
of the appliance, at the top left, as shown in the figure.
To replace the cable, proceed as follows:
3.5
The vitroceramic hob has different power consumptions depending on the type of heating element
used. The diagram shows the values of the power consumed.
In the envisaged cases, the first numeric value refers to the total power, whereas the value that
follows the symbol "/" refers to the inside diameter, with the exception of the central heating
element, whose value that follows "/" refers to the outer diameter.
3.6
The volcanic rock grill has a consumption of 2500W. This appliance must therefore be installed
where this power consumption can be ensured in total safety.
12
Instructions for the installer
open the terminal board box;
unscrew the screw A that locks the cable;
loosen the screw contacts and replace the cable
with one of the same length that corresponds to the
specifications in the table in section "3.4.1 Electric
power cable section";
the "yellow-green" earth wire must be connected to
the terminal
and must be approximately 20 mm
longer than the line cables;
the neutral "blue" wire must be connected to the
terminal marked with the letter N;
the line wire must be connected to the terminal
marked with the letter L.