Selector
No.
1
Delay time for starting detection of
voice signal
2
3
Detection level for no voice signal
4
5
Pause between paging number and
|
PIN
7
8
Not used.
NOTE: Selectors 1 through 4 are not applicable to the U.S.A. versions.
NOTE: Selectors 5 through 7 are applicable to those models equipped with a built-in TAD.
Selectors 1 and 2: Delay time for starting detection of voice signal
These selectors take effect only in TAD mode (when the external TAD is connected to the
machine). The machine delays starting detection of the voice signal by the time length specified by
these selectors.
The total length of the delay time specified by these selectors and the maximum waiting time
specified by WSW21 (selectors 1 through 5) should not exceed 40 seconds.
Selectors 3 and 4: Detection level for no voice signal
These selectors set the detection level for no voice signal in the TAD mode (when the external
TAD is connected to the machine).
Selectors 5 through 7:
These selectors set the pause time between a telephone number being paged and PIN (private
identification number) for the paging feature.
WSW25
Function
Pause between paging number and PIN
28
(TAD setting 3)
Setting and Specifications
No. 1
2
0
0
:
0
1
:
1
0
:
1
1
:
No. 3
4
0
0
:
0
1
:
1
0
:
1
1
:
No. 5
6
7
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
0 sec.
8 sec.
16 sec.
24 sec.
-43 dB (A)
-46 dB (B)
-49 dB (C)
-51 dB (D)
:
2 sec.
:
4 sec.
:
6 sec.
:
8 sec.
:
10 sec.
:
12 sec.
:
14 sec.
:
16 sec.