Brother MFC6800 Service Manual page 140

Multi-function machine
Hide thumbs Also See for MFC6800:
Table of Contents

Advertisement

(11) General communications-related
Code 1
B0
B0
B0
BF
BF
BF
(12) Transmission in V. 34 mode
Code 1
C0
C0
C0
C0
C0
C0
C0
C0
C0
C0
C0
Code 2
02
Unable to receive the next-page data.
03
Unable to receive polling even during turn-around transmission
due to call reservation.
04
PC interface error.
01
Transmission canceled by pressing the Stop key (before
completion of the G3 FAX negotiation).
02
Transmission canceled by pressing the Stop key (after completion
of the G3 FAX negotiation).
03
Transmission canceled due to a scanning error.
Code 2
01
No common modulation mode or failed to poll.
02
Unable to detect JM.
03
Unable to detect CM.
04
Unable to detect CJ.
10
Cannot finish V. 34 negotiation or training.
11
Modem error detected during V. 34 negotiation or training. (For
modem error details, refer to the table given on the next page.)
20
Modem error detected during sending of commands. (For modem
error details, refer to the table given on the next page.)
21
Modem error detected during receiving of commands. (For
modem error details, refer to the table given on the next page.)
22
Control channel connection time-out.
30
Modem error detected during sending of video signals. (For
modem error details, refer to the table given on the next page.)
31
Modem error detected during receiving of video signals. (For
modem error details, refer to the table given on the next page.)
Causes
Causes
6 -1 3