Brother MFC6800 Service Manual page 177

Multi-function machine
Hide thumbs Also See for MFC6800:
Table of Contents

Advertisement

Selector
No.
1
Frequency band selection
(Lower limit)
2
3
Frequency band selection
(Upper limit)
4
5
|
No. of rings in AUTO ANS mode
8
Selectors 1 through 4:
These selectors are used to select the frequency band of calling signals for activating the AUTO
ANS facility.
In the French versions, if the user sets the PBX to OFF from the control panel, the setting made by
selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz. (Even if
the setting made by these selectors does not apply, it will be printed on the configuration list.)
Selectors 5 through 8:
These selectors set the number of rings to initiate the AUTO ANS facility.
WSW14
(AUTO ANS facility setting)
Function
Frequency band selection
No. of rings in AUTO ANS mode
18
Setting and Specifications
No. 1
2
0
0
:
13 Hz
0
1
:
15 Hz
1
0
:
23 Hz
1
1
:
20 Hz
No. 3
4
0
0
:
30 Hz
0
1
:
55 Hz
1
0
:
70 Hz
1
1
:
200 Hz
No. 5
6
7
8
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
:
Fixed to once
:
Fixed to 2 times
:
Fixed to 3 times
:
Fixed to 4 times
:
1 to 2 times
:
1 to 3 times
:
1 to 4 times
:
1 to 5 times
:
2 to 3 times
:
2 to 4 times
:
2 to 5 times
:
2 to 6 times
:
1 to 10 times
:
2 to 10 times
:
3 to 5 times
:
4 to 10 times

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc9160Dcp1000Mfc9180

Table of Contents