Brother MFC6800 Service Manual page 195

Multi-function machine
Hide thumbs Also See for MFC6800:
Table of Contents

Advertisement

Selector
No.
1
ECP* mode
Recovery from inactive PC interface
2
3
PC power-off recognition time
4
Not used.
5
Escape from phase C
6
Lower limit of frequency to be
|
ignored after detection of calling
signals (Ci)
8
Selector 1:
ECP mode
The ECP mode enhances the normal bidirectional communications between the machine and the
connected PC for higher transmission speed.
Selector 2:
Recovery from inactive PC interface
If the machine recognizes via the STROBE signal line that the connected PC is powered off, then
it will turn the PC interface output Low to protect the PC from hazards that could be caused by
weak electric current accidentally flown from the machine.
This selector determines whether the machine should recover from the inactive PC interface to
normal interfacing state upon receipt of data from the PC.
Selector 3:
PC power-off recognition time
This selector sets the time length from when the machine detects the PC powered off until it
recognizes the detected state as power-off.
If selector 2 is set to "0," it is recommended that selector 3 be set to "1": otherwise, the machine
may mistakenly detect PC powered off.
Selector 5:
Escape from phase C
This selector determines whether or not the machine will escape from phase C when it detects an
RTC (Return to Control) in non-ECM mode or an RCP (Return to Control Partial page) in ECM
mode.
Selectors 6 through 8:
At the start of reception, if the machine detects the frequency of calling signals (Ci) specified by
selectors 1 through 4 of WSW14, it will start the ringer sounding. When doing so, the machine
may fail to detect the calling signals normally due to noises superimposed at the time of reception.
To prevent it, use selectors 6 through 8 of WSW36.
If the machine detects higher frequencies than the lower limit specified by these selectors, then it
will regard them as noise and interpret that detecting state as being normal, allowing the ringer to
keep sounding (until the machine starts automatic reception of FAX data if in the FAX mode or
enters the TAD mode if set in the TEL mode, according to the preset number of ringers).
WSW36
(Function setting 14)
Function
Lower limit of frequency to be ignored after detection of calling signals (Ci)
36
Setting and Specifications
0: ON
1: OFF
0: Disabled
1: Enabled
0: Normal
1: Long
0: Yes
1: No
No. 6 7 8
0 0 0
: 0 (Not ignored)
0 0 1
: 4 (448 Hz)
0 1 0
: 8 (244 Hz)
0 1 1
: 12 (162 Hz)
1 0 0
: 16 (122 Hz)
1 0 1
: 20 (97 Hz)
1 1 0
: 24 (81 Hz)
1 1 1
: 28 (69 Hz)
*ECP (Enhanced Capabilities Port)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc9160Dcp1000Mfc9180

Table of Contents