(15) Remove the six screws from the underside of the scanner base.
(16) Release the two latches of the control panel ASSY from the scanner base.
(17) Slightly lift up the control panel ASSY and disconnect the panel harness from the control
panel PCB.
(18) Turn the scanner open sensor actuator as shown below and remove it.
(19) Remove the screw from the scanner open sensor PCB. Then the control panel ASSY is
separated from the scanner unit.
(For the disassembly procedure of the control panel ASSY and scanner unit, refer to
Subsections 4.1.6 and 4.1.7, respectively.)
(20) Remove the lever spring.
(21) Insert the tip of a flat screwdriver into slit "s," push up the lock, and remove the scanner open
lever in the direction of the arrow.
4 -2 3

Hide quick links: