8.4 Batch Default Options

The A/S-4 has the capability of loading all it's Batch options from the VDU (computer) without going
through any menus. This is done by receiving the shift out (X'0E;) character followed by the options
selected in hexadecimal form. The VDU and A/S-4 must be set to receive and transmit an 8-data bit
word with no parity, so all 8 bits of the hexadecimal characters are received. Once all the new Batch
default options are loaded, the A/S-4 is then automatically set to run in the Batch 3776/77 mode. Below
is the Batch options with its bit location.
BYTE
DEFAULT
1
17
2
0C
3
00
4
F7
5
80
6
02
7
01
8
30
9
0F
10
FF
11
07
12
0C
13
01
58
*** SDLC (MODEM) PORT OPTIONS ***
BIT 7 -
6 -
5 & 4 - 00=ASYNC, 01=SYNC
3 THRU 0 = BAUD RATE
0101 = 300 1100 = 4800
0110 = 600 1110 = 9600
0111 = 1200 1111 = 19.2K
1010 = 2400
BIT 5 & 4 - STOP BITS: 00=SYNC, 01=1, 10=1.5, 11=2
3 & 2 - WORD LENGTH: 10=7, 11=8
1 & 0 - PARITY: X0=NONE, 01=ODD, 11=EVEN
BIT 6 & 5 - XON/OFF: 00=OFF, 01=FROM VDU, 10=TO VDU,
1 & 0 - CHAR CODE: 00=EBCDIC, 01=ASCII
SDLC PU ADDRESS
CUSTOMER OPTIONS A
CUSTOMER OPTIONS B
PROTOCOL, 00=3274/76, 01=3776/66
SDLC 3770 XID
*** ASYNC (TERMINAL) PORT OPTIONS ***
*** INBOUND (VDU) LU ***
ASYNC BAUD RATE (1200 BAUD) SEE BYTE 1
WORD LENGTH: 8 - DATA BITS, NO PARITY SEE
BYTE 2
CHAR OPTION: XON/OFF=OFF, ASCII CHARACTERS
11=BOTH