Black Box PC001 User Manual page 73

Protocol converter model a/s-4
Table of Contents

Advertisement

PROTOCOL CONVERTER MODEL A/S-4
&NUMTPBF = nnn
&PRTRANS = YES
* Option not supported
(1) Option determined by max RU size. A/S-4 availablebuffer size = 2100 characters
(2) Option is available but not installed
(3) Option selected by A/S-4 switch settings
The following is a copy of the suggested LOGMODE table for use by the A/S-4:
RJEMODE
MODETAB
BATCH
MODEENT LOGMODE=BATCH,FMPROF=X'03',TSPROF=X'03'
PRIPROT=X'A3',SECPROT=X'A1',COMPROT=X'7080'
MLU1
MODEENT LOGMODE=MLU1,FMPROF=X'03',TSPROF=X'03',
PSNDPAC=2,SRCVPAC=1,PRIPROT=X'A8',SECPROT=X'A1',COMPROT=X'7080'
MLU2
MODEENT LOGMODE=MLU2,FMPROF=X'03',TSPROF=X'03',
PSNDPAC=4,SRCVPAC=2, PRIPROT=X'A3'SECPROT=X'A1',COMPROT=X'7080'
MLU3
MODEENT LOGMODE=MLU3,FMPROF=X'03',TSPROF=X'03',
PSNDPAC=6,SRCVPAC=3, PRIPROT=X'A3',SECPROT=X'A1',COMPROT=X'7080'
INTERACT
MODEENT LOGMODE=INTERACT,FMPROF=X'03',TSPROF=X'03',
PRIPROT=X'B1',SECPROT=X'A0',COMPROT=X'3040'
NOCOMP
MODEENT LOGMODE=NOCOMP,FMPROF=X'03',TSPROF=X'03',
PRIPROT=X'A1',SECPROT=X'A1',COMPROT=X'7080'
COMP
MODEENT LOGMODE=COMP,FMPROF=X'03',TSPROF=X'03',
PRIPROT=X'A3',SECPROT=X'A1',COMPROT=X'7080'
BUF512
MODEENT LOGMODE=BUF512,FMPROF=X'03',TSPROF=X'03',
RUSIZES=X'8686', PRIPROT=X'A3',SECPROT=X'A3',COMPROT=X'7080'
BUF256
MODEENT LOGMODE=BUF256,FMPROF=X'03',TSPROF=X'03',
RUSIZES=X'8585', PRIPROT=X'A3',SECPROT=X'A3',COMPROT=X'7080'
COMPACT
MODEENT LOGMODE=COMPACT,FMPROF=X'03',TSPROF=X'03',
RUSIZES=X'8585', PSERVIC=X'01106000F100808000010040',
PRIPROT=X'A3',SECPROT=X'A1',COMPROT=X'7080'
MODEEND
END
72
Number of JESX Data Communications Buffers
Print Line Translation Option, looks for chars less than X '40'
and if so sends data as transparent

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc006A/s-4

Table of Contents