Chassis - Cisco SD2008T-NA Installation Manual

Hardware installation guide
Hide thumbs Also See for SD2008T-NA:
Table of Contents

Advertisement

Cisco Nexus 2232PP

Chassis

The Cisco Nexus 2232PP FEX chassis has a height of 1.72 inches (4.37 cm), a width of 17.3 inches
(43.94 cm), and a depth of 17.7 inches (44.96 cm). It weighs 18.3 pounds (8.3 kg) and supports vertical
orientation. Its one-rack-unit (1 RU) form factor takes up relatively little space, making it easy to
incorporate into rack designs. The FEX is mounted in a standard 19-inch (48.26 cm) rack. All of the
switch ports at the rear of the chassis are in close proximity to server ports, and all user-serviceable
components are accessible from the front panel.
You can order front-to-back airflow or back-to-front airflow for cooling. If you are going to install the
chassis with its front end facing the cold aisle, you must order the chassis with front-to-back air flow. If
you are going to install the chassis with its back end facing the cold aisle, you must order the chassis
with back-to-front airflow.
Figure 1-23
location of components on the rear of the chassis. For information on what the chassis and component
LEDs indicate, see
Figure 1-23
1
2
Cisco Nexus 2000 Series Hardware Installation Guide
1-24
shows the location of the components on the front of the chassis, and
Table D-1 on page
Front View of the Cisco Nexus 2232PP Chassis
1
2
Power supply
Fan tray
Chapter 1
Using a Fabric Extender with a Cisco Nexus 5000 Series Switch
D-2.
3
4
3
Power supply (blank module shown)
4
Status (top) and ID (bottom) LEDs
Figure 1-28
shows the
OL-19013-05

Advertisement

Table of Contents

Troubleshooting