Gas Adjustment (Conversion To Lpg And Flow Adjustment) - Baumatic Royal Chiantishire BRC3BDY User Manual

90 cm multi-function twin cavity cooking theatre
Table of Contents

Advertisement

G
as adjustment (Conversion to LPG and flow adjustment).
All w
ork must be carried out by a CO
engineer.
I
MPORTANT: Always isolate the cooker from the electricity
su
pply before changing the injectors and/or adjusting the
mi im
n
um flow of the burners.
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o Remove the pan-stands, burners and
flame spreaders (A).
o Unscrew the injector (B) and replace it
with the stipulated injector for the new gas
supply (see table below).