Disconnect the gas pipe from the gas tap, disassemble from the gas rail by removing the
fixing screws.
When fitting a new tap, ensure that a new gasket is used.
Re-connect the gas tap, check for gas soundness and reassemble the hob.
ELECTRICAL DETAILS
Rated Voltage
Supply Connection
Power Input
Mains supply lead
GAS DETAILS
Connection
Type
BURNER TYPES AND POWER INPUTS : kW
Model
Large
Max / Min
AS9.1AL VALV
3.0 / 0.7
B40
3.0 / 0.9
B72TCBL
-
B77TCBL
3.0 / 0.7
B78
3.0 / 0.7
JET SIZING CONVERSION TABLE: NATURAL GAS / LPG
Model
AS9.1AL VALV
B40
B72TCBL
B77TCBL
B78
10

TECHNICAL DATA

230V ac 50Hz
13A (double pole switched fused outlet with 3mm contact gap)
0.008 to 0.02kW (depending on model)
3 x 0.75mm2 Type RR-F <HAR> marked
Rp ½ (ISO R7)
Natural Gas (20.9 mbar) – alternative LPG G30 (28-30 mbar)
[Town Gas G110 – 120 (8 mbar) to order]
Medium
Max / Min
1.75 / 0.4
1.75 / 0.4
1.75 / 0.4
1.75 / 0.4
1.75 / 0.4
Large
Medium
NG / LPG
NG / LPG
1.15 / 0.85
0.97 / 0.65
1.15 / 0.85
0.97 / 0.65
-
0.97 / 0.65
1.15 / 0.85
0.97 / 0.65
1.15 / 0.85
0.97 / 0.65
Small
Wok
Max / Min
Max / Min
1.0 / 0.35
3.5/1.7
-
3.8 / 1.75
1.0 / 0.35
3.5/1.7
1.0 / 0.35
3.5/1.7
1.0 / 0.35
3.5/1.7
Small
NG / LPG
0.72 / 0.50
-
0.72 / 0.50
0.72 / 0.50
0.72 / 0.50
Fish
Total
Max / Min
KW
-
11.0
-
8.55
-
11.0
-
11.0
-
11.0
Wok
Fish
NG / LPG
NG / LPG
1.35/0.95
-
1.35 / 0.98
-
1.35/0.95
-
1.35/0.95
-
1.35/0.95
-