ELECTRICAL CONNECTION

This appliance must be installed by a competent person, such as one holding NICEIC Registration
and in accordance with the latest edition of the IEE WIRING Regulations.
Before connecting the appliance, make sure that the supply voltage marked on the rating Plate
corresponds with the mains supply voltage.
WARNING – THIS APPLIANCE MUST BE EARTHED
Depending on the Power Input of the model to be installed, connection will require a 16Amp or
30Amp protected supply using a switched double pole isolating unit having a minimum 3mm
contact separation and a BS6007 3-core cable (see Technical Data at page 11 for full
information).
Care must be taken to avoid the cable being in contact with hot parts of the appliance.
The isolating unit should be placed in an easily accessible position adjacent to the appliance.
NOTE
The appliance must not be connected to the mains supply by means of a 13A plug and
socket.
MAINTENANCE
During the guarantee period, in case of need all service intervention should be referred
back to the Baumatic Ltd Service department. Please note that intervention or repair by
any unauthorised personnel will invalidate such guarantee.

ELECTRICAL DETAILS

Rated Voltage:
Supply Connection:
POWER INPUTS AND PROTECTION RATING
Model
B11SS
Mains Supply Connection Cable:
NOTE:
For cable connection details, see diagram on appliance base plate.
6

TECHNICAL DATA

230V ac 50Hz
Switched Double-pole Isolator with 3mm contact separation
Max
kW
5.8
3 x 2.5mm2 Type H05 RR-F <HAR> marked
Total
Amps
25.2
Min Fuse
Protection Rating
30A