Technical specifications

Enclosure specifications

AC power
requirements
Table A-1
Requirement
AC line voltage
AC line current
Power consumption
Power factor
Heat dissipation
In-rush current
Startup surge current
AC protection
AC receptacle type
Ride-through time
Current sharing
DAE2P/DAE3P Hardware Reference
A-2
Technical enclosure specifications include power requirements, size,
drive, interface, and standards information.
The input current, power (VA), and dissipation per DAE2P/DAE3P
are based on the requirements that a maximum enclosure
configuration places on the power supplies and cooling system to
provide internal regulated power. Typical values will be less,
depending on the number and manufacturer of disk modules. These
values represent either
the values for a single power supply line cord, or
the sum of values shared by the line cords of two power supplies
in the same DAE2P/DAE3P, with the division between the line
cords and supplies at the current sharing ratio (approximately
50% each).
A failure of one of the two power supplies in the enclosure results in
the remaining supply and cord supporting the full load. You must
use a rackmount cabinet with AC power distribution, and have main
branch AC distribution that can handle these values for each disk
enclosure in the cabinet.
DAE2P/DAE3P AC power specifications
100 to 240 V AC + 10%, single phase, 47 to 63 Hz
50 A max for 1/2 line cycle, per power supply at 240 V ac
25 A max for 1/2 line cycle, per power supply at 120 V ac
15 A pk (10.6 A rms) max for 100 ms, at any line voltage
10 A fuse in each power supply, both phases
IEC320-C14 appliance coupler, per power supply
60% max, 40% min, between power supplies
* Ratings assume a fully configured DAE2P/DAE3P that includes two power supplies,
two LCCs, and 15 disk drives.
Description *
4.4 A at 100 V ac, 2.2 A at 200 V ac
440 VA(425 W) max (fully configured)*
0.98 min at full load, low voltage
6
1.53 x10
J/hr (1,450 BTU/hr) max
30 ms min