Servicing a DAE2P/DAE3P
Replacing a power supply/system cooling module
Figure 3-15
3-20
DAE2P/DAE3P Hardware Reference
CAUTION
!
Handle a power supply/system cooling (power/cooling) module
gently and use an ESD wristband. Do not remove a power/cooling
module until you have a replacement module available.
Access to the disks in your enclosure will time out and the disks
will spin down two minutes after a power/cooling module is
removed from the enclosure. While the system can continue
operating on a single power supply, the loss of a module's two
blowers will cause a time-out unless you replace the module within
two minutes.
When replacing a power/cooling module, make certain the green
LED on one module has been steadily on for at least 5 seconds
before removing power from the second module.
Follow these steps to replace a power/cooling module.
1. Unplug the AC line cord as shown in
Retention Bail
Unplugging the AC power cord
2. Turn the captive screw counterclockwise to release the module,
and then remove the power/cooling module as shown in