HP StorageWorks 8/8 - SAN Switch Release Note page 39

Hp storageworks fabric os 6.2.0g release notes (5697-0355, march 2010)
Hide thumbs Also See for StorageWorks 8/8 - SAN Switch:
Table of Contents

Advertisement

Under Port Base Routing, topologyshow always shows None for the
In Port field on HP StorageWorks 8/8, 8/24, and 8/40 SAN Switches.
HCL on switch continues if sent Pause frame is rejected by attached
M-EOS switch. HCL on switch will sometimes continue, even when a
sent Pause frame is rejected by another switch in the fabric.
N_Port on Edge_AG_200E_PG got disabled with reason code Initi-
ator/target connected to N-Port.
Firmware download of Fabric OS 6.1.0 is allowed on an embedded
blade that should not allow it.
Fabric Rebuild during HP StorageWorks 8/40 SAN Switch HCL when
1 of 2 Backbones connect to a M6140 director.
If Turboramtest is performed, the Telnet console will disconnect.
Incorrect error when changed switchname for more than 24 charac-
ters through CLI in FMS mode.
F_Ports on HP StorageWorks 8/8 and 8/24 SAN Switches AG cannot
login, and become G_Ports.
Occasionally an LD port gets into a lock up state that causes port-
GetVCCredits get failed and the ISL segments with LD incomp,
although portcfgshow shows both sides of ISL config are the same.
EE monitor counters may not get updated after performing switch-
disable/switchenble or reboot.
Static routing does not affect dynamic routes with DLS ON on supported
platforms.
The gzoneinfo.htm page returns empty data when CLI actually
shows defined/eff cfg zone info for fabric.
Third-party storage center application does not survive in an FCIP
network with 1% packet loss and 100 ms network latency.
Traffic Isolation failover policy reverts back to disabled from enabled
after changing the port membership list.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use urouteshow to view the 'Out
Port' selected for a particular 'In Port'
to a domain when using Port Based
Routing.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reset with portcfgdefault/port-
cfgqos.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Retrieve all EE monitors from the
FLASH by issuing perfcfgrestore.
All EE monitor counters will be prop-
erly updated.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Do any other HTTP post operation
from DCFM and then you see both
the old data and the newly pushed
zone info. Rebooting the switch
sometimes helps.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
HP StorageWorks Fabric OS 6.2.0g release notes
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents