HP StorageWorks 8/8 - SAN Switch Release Note page 38

Hp storageworks fabric os 6.2.0g release notes (5697-0355, march 2010)
Hide thumbs Also See for StorageWorks 8/8 - SAN Switch:
Table of Contents

Advertisement

After hareboot, Probing failed on F_Port messages may be
seen on the HP StorageWorks 8/8, 8/24, 8/40, and 8/80 SAN
switches.
HP 400 MP Router panicked after TI zone activation.
B-series Multi-protocol Router blade faulted after overnight stress testing.
Received error message with high temperature (89) on edge HP Stor-
ageWorks DC SAN Backbone Director in fabric.
The portcfgnpivport CLI command will not toggle trunked slave
ports if the user disables NPIV configuration on that port.
Faulted (51) core blade due to POST failure, resulted from overnight
power cycle test.
After attempting cfgdisable on a system in native interopmode and
with default zoning set to all access and a large zoneset of at least
460 devices, the switch became faulty.
No F_RJT's being returned for class 2 frames that are not routable ac-
cording to a QoS/TI configuration.
B-series Multi-protocol Router blade failed to do blade firmwaredown-
load.
Switch reboots when IFL is enabled.
Frame drop observed after creating a TI zone with failover enabled
in the backbone fabric ( TI over FCR).
Hard Zoning disabled when ports toggle.
Pathinfo doesn't match urouteshow and rtedebug.
Sensors show incorrect command output in fully loaded HP Storage-
Works DC SAN Backbone Director.
Update to VC assignment scheme within core ASIC management
structure.
Fast Write performance issue with a particular FCIP Ex_Port configur-
ation.
38
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Do not configure an FCIP Tunnel.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
The user must manually toggle (en-
able/disable) the slave port to com-
plete the operation.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable the diagnostic POST, then
slotpoweroff on the faulted core
blade.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Perform slot power off / slot power
on the blade that timed out.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable FCR routing and Ex_Ports and
merge the fabric into one large fabric.

Hide quick links:

Advertisement

Table of Contents
loading