Fabric OS 6.2.0 fixes
The following table lists defects closed in the Fabric OS 6.2.0 firmware release.
Table 8 Fabric OS 6.2.0 closed defects
Closed defect summary
Add Member button is disabled while creating a new TI Zone when
the switch is in VF mode.
Under stress testing, cfgsave takes a long time and fails to propagate
on 64 VE-VE FCIP tunnel 33 switch core-edge topology running I/O.
Adding a B-series switch with conflicting domain ID into an EOS fabric
may cause another switch to segment.
USB port LED of HP StorageWorks DC SAN Backbone Director CP
blade stays ON after HA failover.
CUP Port stuck in Contingent Allegiance State after z9 Host IPL.
Spinfab and porttest (diagnostics) are not supported on ICL ports.
Bogus core_file created and transferred after the first reboot after a
firmwaredownload.
B-series Multi-protocol (MP) Router blades in HP StorageWorks DC
SAN Backbone Director chassis may fail sysverification tests.
With a switch in Interop Mode 2 or 3, the Zoning configuration is not
being included in configupload.
FICON Channel continuously sends RRQ frames for approximately 20
seconds before aborting.
If QoS and Diff Serv are enabled, some FCIP tunnels may not come
online in the case of an 8 to 1 fan-in scenario.
Under rare conditions, fabric mode TopTalker monitor does not display
correct flow values.
Attempting to configure port mirroring on a director with both 4Gb
and 8Gb blades may result in a software Verify error.
34
Solution
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Add Other Port button can be used to
add ports. This is available in the
ADD TI Zone window.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Wait until fabric is not saturated to
push configs around.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Check the domain ID before adding
a switch to any fabric.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Rerun system verification.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Port disable/enable the VE-Port
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.