Hot-Plug Scsi Hard Drive Led Combinations - HP DL560 - ProLiant - 1 GB RAM User Manual

Hp proliant dl560 server user guide
Hide thumbs Also See for DL560 - ProLiant - 1 GB RAM:
Table of Contents

Advertisement

24
HP ProLiant DL560 Server User Guide

Hot-Plug SCSI Hard Drive LED Combinations

Activity
Online
LED
LED
On
Off
On
Flashing
Flashing
Flashing
Off
Off
Off
Off
Off
On
On or
On
flashing
Fault
Means
LED
Off
Do not remove the drive. Removing a drive during this
process causes data loss. The drive is being accessed and is
not configured as part of an array.
Off
Do not remove the drive. Removing a drive during this
process causes data loss. The drive is rebuilding or undergoing
capacity expansion.
Flashing
Do not remove the drive. Removing a drive during this
process causes data loss. One of the following conditions may
exist:
The drive is part of an array being selected by ORCA.
The Options ROMPaq is upgrading the drive.
Off
One of the following conditions may exist:
The drive is not configured as part of an array.
If this drive is part of an array, a powered-on controller is not
accessing the drive.
The drive is configured as an online spare.
It is OK to replace the drive online if a predictive failure alert is
received and the drive is attached to an array controller.
On
The drive has failed and has been placed offline. It is OK to
replace the drive online.
Off
The drive is online and configured as part of an array. It is OK to
replace the drive online if a predictive failure alert is received,
provided that the array is configured for fault tolerance and all
other drives in the array are online.
Off
The drive is online and is being accessed. It is OK to replace the
drive online if a predictive failure alert is received, provided that
the array is configured for fault tolerance and all other drives in the
array are online.