Table 58. Virus Related Bios Messages; Table 59. System Configuration Bios Messages - Intel SE7525RP2 Technical Manual

Technical product specification
Hide thumbs Also See for SE7525RP2:
Table of Contents

Advertisement

Intel® Server Board SE7320EP2 / Intel® Server Board SE7525RP2 TPS
Error Logging
Message Displayed
S.M.A.R.T. Command Failed
S.M.A.R.T. Status BAD, Backup and
Replace
S.M.A.R.T. Capable and Status BAD
Message Displayed
BootSector Write !!
VIRUS: Continue (Y/N)?
Message Displayed
DMA-2 Error
DMA Controller Error
Checking NVRAM..Update Failed
Microcode Error
NVRAM Checksum Bad, NVRAM Cleared
Resource Conflict
NVRAM Ignored
NVRAM Bad
98
The BIOS tried to send a S.M.A.R.T. message to a hard disk, but the
command transaction failed.
This message can be reported by an ATAPI device using the S.M.A.R.T.
error reporting standard. S.M.A.R.T. failure messages may indicate the
need to replace the hard disk.
A S.M.A.R.T. capable hard disk sends this message when it detects an
imminent failure.
This message can be reported by an ATAPI device using the S.M.A.R.T.
error reporting standard. S.M.A.R.T. failure messages may indicate the
need to replace the hard disk.
A S.M.A.R.T. capable hard disk sends this message when it detects an
imminent failure.
This message can be reported by an ATAPI device using the S.M.A.R.T.
error reporting standard. S.M.A.R.T. failure messages may indicate the
need to replace the hard disk.

Table 58. Virus Related BIOS Messages

The BIOS has detected software attempting to write to a drive's boot sector. This is
flagged as possible virus activity. This message will only be displayed if Virus Detection
is enabled in AMIBIOS setup.
If the BIOS detects possible virus activity, it will prompt the user. This message will only
be displayed if Virus Detection is enabled in AMIBIOS setup.

Table 59. System Configuration BIOS Messages

Error initializing secondary DMA controller. This is a fatal error, often
indication a problem with system hardware.
POST error while trying to initialize the DMA controller. This is a fatal
error, often indication a problem with system hardware.
BIOS could not write to the NVRAM block. This message appears
when the FLASH part is write-protected or if there is no FLASH part
(System uses a PROM or EPROM).
BIOS could not find or load the CPU Microcode Update to the CPU.
This message only applies to INTEL CPUs. The message is most likely
to appear when a brand new CPU is installed in a motherboard with an
outdated BIOS. In this case, the BIOS must be updated to include the
Microcode Update for the new CPU.
There was an error in while validating the NVRAM data. This causes
POST to clear the NVRAM data.
More than one system device is trying to use the same non-shareable
resources (Memory or I/O).
The NVRAM data used to store Plug'n'Play (PnP) data was not used
for system configuration in POST.
The NVRAM data used to store Plug'n'Play (PnP) data was not used
for system configuration in POST due to a data error.