Chapter 13
NOTE
Use the HP Rack Configuration Tools to determine where in
the rack to mount the HP Netserver.
1. Find the EIA unit markings on the rack and the location for the Netserver.
The screw holes cover a span of only one EIA unit, which is the height
requirement of the HP Netserver.
NOTE
The Netserver can only be mounted into both holes of one EIA
Unit, but cannot be mounted across two EIA units. You cannot
use a hole in one EIA unit and a hole in another EIA unit.
2. Use the masking tape (or marking pen) to mark above the 3rd hole up on
both front columns, as shown in Figure 13-3.
represents
the EIA unit
numbers on the
rack columns.
3rd Hole
From Bottom
1st Hole
From Bottom
Figure 13-3. Location Marks on the Rack's Columns
3. Mark the forward face and edge of the left-rear and right-rear rack
columns, with masking tape, as shown in Figure 13-3.

Attaching Outer-Rails to the Rack

1. Pull the anti-tip foot forward out of the bottom of the rack.
See Figure 13-4 for the anti-tip foot location.
6
Left
Masking
Side
Tape
Marker
Bottom of
HP NetServer
Alternative Rack Mounting (4–Post)
Rear of
Rack
Mark this face and
Right
edge of the columns
Side
with masking tape
or marking pen, as
shown.
Front of
Rack