IEEE organization recommends maximum optical fiber cable distances as defined in the following table.
Standard
10BASE-FL
100BASE-FX
100BASE-SX
1000BASE-SX 1000
1000BASE-LX 1000
1000BASE-LH 1000
Connecting the Fiber Port (RocketLinx ES8108F)
Data Rate
Cable Type
(Mbps)
10
850nm, 50/125um or 62.5/125um
Multi-Mode optical fiber cable
100
1310nm, 50/125um or 62.5/125um
Multi-Mode optical fiber cable
100
850nm, 50/125um or 62.5/125um
Multi-Mode optical fiber cable
850nm, 50/125um
Multi-mode optical fiber cable
850nm, 62.5/125um
Multi-Mode optical fiber cable
1310nm, 50/125um or 62.5/125um
Multi-mode optical fiber cable
1310nm, 9/125um
Single-Mode optical fiber cable
1550nm,9/125um
Single-Mode optical fiber cable
IEEE Standard
Distance
2km
2km
300m
550m
220m
550m
5km
70km